Phone 203.853.8080 Fax 203.299.0232 |
 |
|
|
|
|
|---|
|
|
| RIGrunner 8012 - 4010S - 4012 - 4008 - 4005 |
| Overall Dimensions (maximum, w/o cables) |
1.4" H x 11.75" (4010S, 8012 & 4012), 9" (4008), 6" (4005) W x 3.0" D |
| Weight |
15 1/4 (4010S, 8012 & 4012), 11 1/4 (4008), 6 3/4 (4005) oz. |
| Maximum total current |
40 amps (4010S - 4012 - 4008 - 4005) 80 amps (8012) |
| Maximum single individual outlet current |
40 amps (fuse protected, all models) |
| ICAS current rating (fuse limited) |
37 amps (4010S - 4012 - 4008 - 4005) 74 amps (8012) |
| Precision comparator window points. |
11.5,15.0 Volts (8012, 4010S, 4012, 4008 only) |
| Metering Accuracy |
better than 2% @ 25 deg.C. (8012, 4010S, 4012, 4008 only) |
| Audible alert SPL output |
~ 60dB SPL @ 1 meter (8012, 4010S, 4012, 4008 only) |
| Maximum voltage (meter circuit) |
32 volts (8012, 4010S, 4012, 4008 only) |
| Reverse polarity protection (meter circuit) |
Yes (8012, 4010S, 4012, 4008 only) |
| 4010S Automatic switching threshold. |
Most radios with appropriate master outlet fuse. |
|
|
|