Phone 203.853.8080 Fax 203.299.0232 |
 |
|
|
| CBA Owners Manual On-Line |
|
| CBA Owners Manual translated
to German On-Line |
|
| CBA Owners Manual in Acrobat .pdf format |
| This manual is in Acrobat .pdf format. You will
need Adobe Acrobat Reader (included on our CD) to read it. |
|
| Download the Latest Software for the West Mountain Radio CBA |
| Click Here to Download
Software Version 1.0.8.1 |
| This new version, 1.0.8.1, released May 5, 2005, has many subtle updates with
fixes of most reported issues plus several new features and an updated help file.
This new version has a new CSV export utility to provide a full test information header to be included with the export. There is a new Lab Calibrate
feature for advanced users and there is compensation for the most accurate voltage readings directly at the CBA's Powerpole connector.
Version 1.0.7.1 through this version, 1.0.8.1 supports 12 bit high accuracy current set mode. The 12 bit current mode allows high resolution
current set below 3 Amps and operation below 0.5 amps. This software version is downwardly compatible with the original CBA units but the operation
for older units is not updated by the software. An older CBA MK I requires a hardware/firmware update which is available (see below).
This update is a self extracting .exe file. Download and "run" this update but make sure that you DO NOT have the old CBA program running when you
install this update.
|
| Plug and Play driver installation if you lost your CBA CD ROM |
| If you have lost your CD ROM and are installing the CBA on a
new computer you may install the drivers after installing the software from the download link above. After installing the software the
drivers will be located in the installation directory normally at: C:/Program Files/West Mountain Radio/CBA/Drivers.
Plug in the CBA and Windows should pop up a "New hardware found" window. "Tell" the hardware installation wizard that you
"have disc" and browse to C:/Program Files/West Mountain Radio/CBA/Drivers and continue. The CBA drivers will be installed and the
CBA should be ready to use.
If you already plugged in the CBA and the drivers were not correctly installed because you didn't know where the drivers were located
then open, Start, Settings, Control Panel, System, Hardware, Device Manager and find the incompletely installed "WMR CBA".
Right click and highlight the CBA and select "Properties". Select "Drive" and re-install the drivers by telling Windows that
the drivers are located at C:/Program Files/West Mountain Radio/CBA/Drivers. You may have to re-boot your computer to put the correct driver
installation into effect.
|
| Lab Calibrate feature in version 1.0.8.1 Software |
| Each and every CBA is individually calibrated with a precision computerized
calibration setup. The typical accuracy of a CBA is better than plus or minus 1% PLUS, plus or minus one data level.
In order to have the CBA operate over the range of 0-40 Amps there must be some engineering trade-offs. We have two different current setting modes
in a CBA II. The way that the CBA II works below 3 amps is to set its current by using a lookup table. This is done with 12 bit resolution according
to individually calibrated tables in each CBA. 12 bits means that there are 4096 digital level steps from 0 to 3 amps: approximately .001 Amps each.
From 3 to 40 amps discharge we set the current approximately and using software feedback set the current to match the reading of the CBA's
individually calibrated internal current measuring circuit. This measurement is done with 10 bit resolution, 1024 steps, or approximately .05 amps per
step.
For a user seeking the highest possible accuracy it we have included a feature in the software to calibrate the CBA's current against a very accurate
external amp meter. We only recommend doing this if you are discharging at 0.1 amps or lower and you own a lab grade ammeter capable of measuring current
better than plus or minus 0.5 % accuracy.
To use this feature simply connect your external meter and run a battery test in the current range that you wish to run at. Note the difference
between the CBA's current reading and your external meter. From the software then set in that difference in current. Re-start the test to see the results
of changing the calibration. You should be able to achieve one data level better accuracy.
Be aware that the CBA is more accurate than most hobby grade meters so do not attempt to calibrate a CBA against anything except precision lab equipment.
|
The CBA works but I have problems with the LEDs or fan or other strange behavior.
There are two possible causes for this behavior, either the CBA is plugged
in to an external USB hub (instead of directly to USB port built in to the computer) or several users have reported that they did not follow the Windows
Plug&Play driver installation prompts carefully and allowed Windows to "choose" the incorrect driver for the CBA instead of "telling"
Windows to use the correct driver only available on the CBA CD ROM.
Go to "Start", "Settings", "Control Panel" and continue until you find the CBA driver files installed. To help find the files from the
Control Panel".
Look at our screen shot of the windows and tabs that must be selected through in number order to find the driver information:
Driver check screens
You MUST see at least the two files Cygf32x.sys and CygLib.sys listed as driver files. If these two files are not there, DO NOT expect
your CBA to work!
To fix this you must remove the incorrect driver files and re-install the correct files directly from the CBA CD ROM. Note: the driver files
may also be found at C:/Program Files/West Mountain Radio/CBA/Drivers/ . We are sorry but we cannot exactly describe procedure to
fix an incorrect installation as the procedure is different with different versions of Windows.
Once you have successfully corrected an incorrect installation you will see the correct driver files listed.
|
Do not use Windows hibernate or sleep modes.
It appears that certain computers and versions of Windows that USB ports are disabled, ignored or some how made
inoperative when various power saving features automatically activate.
Even thought we recommend against running unattended battery tests, at least one person walked away while his computer
went to sleep and over-discharged a battery.
The only sleep mode we would recommend is turning off your monitor. Suspending hard drives, hibernating and other power
saving schemes are not compatible with sustaining the necessary USB communication to run a battery test.
Right click anywhere on your desktop, click Properties, Screen Saver and then Power. Check to make sure that the time
for these features to activate is either much longer than your proposed battery tests or disable all power saving features.
Some computers may have a way to leave the USB port on and therefore inhibit sleep modes with USB communication active. |
|
Windows XP users.
When installing our software you will get a message from Microsoft that they do not certify our software.
This message means that we did not pay them tons of money. Ignore the message and continue and complete the installation. |
|
Nothing Happens When you Click to Install the CBA Software.
If you cannot install the CBA program (nothing happens after you click install
from our CD or our support download)
You may have an issue with your Windows MSI (Microsoft Installer System) support which makes it impossible to install any program, like ours, that has
an install package written with the Microsoft installer.
Go to this Microsoft Support page and follow the
instructions to resolve this problem. |
|
| Original CBA I to CBA II firmware update information
|
|---|
If you have not already installed a recent software version, 1.0.7.1 or higher,
install the newest version above. Go to "Help" "About" and check if your hardware supports high accuracy DACurrent mode. If it does support DACurrent
mode you have the latest CBA MK II version and you do not need or want an update.
If you have the old unit you may wish to have the update done by us. The major improvement will be four times the current set resolution only below
3 Amps and you will also be able to conduct tests below 0.5 amps.
If you would like the hardware/firmware update for your older unit it is $10 plus shipping. Return, only, your original CBA unit without cables or
CDrom. Go to our order page and purchase the update, on-line, before we have received your unit back for update. , click
HERE
to select where you want it shipped back to. Be sure to order your update before returning your unit. For details click "More Information" next to the
CBA Update purchase item.
|
|
|
|
|---|
|
|---|
|
|---|
|
|---|
|
|---|
|
|---|
|
|---|
© West Mountain Radio
|